Technical Specifications
| Model | HVAC-1 | HVAC-2
|
|---|
| Output | 2500 ml/hr | 4950 ml/hr
|
|---|
| | 8200 mg/hr | 16400 mg/hr
|
|---|
| Coverage | up to 2500 sq ft | up to 5000 sq ft
|
|---|
| Price | |
|
|---|
|
: Maximum square footage is only an estimate and is based on mild conditions with a low ceiling height. Actual coverage will vary depending on many factors. Please consult a product specialist for your application.
|
Item Includes
INCLUDED ITEMS:
- HVAC air purifier (and attached mounting plate).
- 6 Ft. length flexible wiring conduit.
- Gasket material
- Mounting screws
|
Installation Notes
HVAC1 SPECIFICATIONS AND INSTALLATION INSTRUCTIONS
ATTENTION! READ BEFORE INSTALLING
CAUTION: The HVAC1 and 2 are special air purifiers designed for a specific application.
The Aran™ generator is exposed to allow for proper airflow once inserted into the ductwork.
Great care should be taken when handling the unit prior to installation.
Do not subject the unit to rough handling once removed from its packaging.
Do not expose the Aran™ generator to contamination by foreign objects or particles.
The unit is a high voltage electrical device and should be installed by a professional.
The unit should never be operated or wired to power without being securely mounted into a duct.
WIRE COLOR CODES:
- GREEN = GROUND
- WHITE = COMMON
- BLACK = HOT
POWER REQUIREMENTS:
120 VAC @ .5 AMPS
75 WATTS NOMINAL
MAXIMUM ARAN™ OUTPUT: 2750 ml/Hr. Aran™
CONTROL BOX DIMENSIONS: 3" Depth X 4 3/4" Height X 7 1/4" Length
HVAC1 Overall Dimensions (Control and Mounting Plate): 7 1/2" Depth X 8" Height X 12" Length
WEIGHT: 8 Lbs.
NEXT